AeroPOWER® FIREZONE M25038/3 Cables are built specifically to withstand the extreme temperatures of an aircraft engine environment and other harsh environments.
» Voltage Rating: 600 V
» Temperature rated to 260 C
» Meets or exceeds the MIL-DTL-25038/3 requirement
» Fire Resistant: 15 minutes at 2000 F
» Insulation Resistance meets 50 Ohms requirement up to 15,000 Ohms on 20 AWG
» Thermal Shock 0.060" max change
» Meets high-temperature endurance requirements:
- 100 hours at 343 C
- Fluid immersion
- Bend
- Wet Dielectric
Part Number |
Size (AWG) |
Stranding |
Conductor Diameter (Nom) |
Conductor DC Resistance (ohms/1000 ft) Max |
Cable Diameter (Min) |
Cable Diameter (Max) |
Cable Weight (lbs/1000 ft) Nom |
V00322-* | 22 | 19 x 34 | 0.0296 | 23.7 | 0.040 | 0.054 | 4.14 |
V00322H-* | 22 | 19 x 34 | 0.0296 | 23.7 | 0.055 | 0.075 | 6.00 |
V00320-* | 20 | 19 x 32 | 0.0376 | 15.27 | 0.048 | 0.083 | 9.00 |
V00318-* | 18 | 19 x 30 | 0.0470 | 8.5 | 0.065 | 0.097 | 10.50 |
V00316-* | 16 | 19 x 29 | 0.0530 | 6.66 | 0.068 | 0.103 | 13.50 |
V00314-* |
14 | 19 x 27 | 0.0670 | 4.32 | 0.097 | 0.123 | 19.50 |
V00312-* | 12 | 19 x 25 | 0.0890 | 2.78 | 0.100 | 0.142 | 28.00 |
*Customer can designate color code per slant sheet
¹V00322H-*: The 22H wire is defined as heavy-wall or thick-wall version of size 22 wire for use in specific applications. It is considered to be “light weight, small diameter” when compared with the normal weight size 22 of MIL-DTL-25038/1. The 22H wire should only be used with a size 20 type contact for MIL-DTL-38999 connectors.
Harbour Industries
802-985-3311
This email address is being protected from spambots. You need JavaScript enabled to view it.
This email address is being protected from spambots. You need JavaScript enabled to view it.